This web page contains a live and functional spreadsheet created with
SpreadsheetConverter
. Please enable JavaScript in your web browser for the live calculations to work properly.
INSTRUCTIONS
INSTRUCTIONS
HEAT INPUT
GAS RATE SHEETS
VENT CALC
PURGING
COMBUSTION PA
BE AWARE THAT MANUFACTURERS INSTRUCTIONS
ARE ALWAYS TAKEN AS CORRECT
IN WHICH CASE THE CALCULATORS MAY NOT BE REQUIRED
1
SELECT THE TAB AT THE BOTTOM VENTILATION OR
PIPE SIZING OR PURGING ETC
2
FILL IN THE DETAILS IN THE YELLOW BOXES ONLY
IF INFORMATION IS PLACED IN A WRONG BOX THE PROGRAM
WILL TELL YOU
3
THE INFORMATION YOU REQUIRE WILL APPEAR IN THE
BLUE BOX
any questions email
enquire@gb-gas.co.uk
or visit
www.gb-gas.co.uk
AIM TO PASS WITH GB GAS
this is a free domestic gas calculator all calculations are deemed to be correct. Using this calculator will be covered by the disclaimer www.gb-gas.co.uk/disclaimer_5.html for more details
HEAT INPUTS
METRIC METER
IMPERIAL METER
AMOUT OF GAS
TIME FOR
(1FT3) ONE
USED IN TWO MINS
REVOLUTION IN SECONDS.
first reading
second reading
GAS RATE
m3/hr
HEAT INPUT NET
kW
HEAT INPUT GROSS
kW
METRIC METER GAS RATES
0.001
>
0.03
>
>
>
>
m3 / two mins
gas rate
kw net
kw gross
m3 / two mins
gas rate
kw net
kw gross
m3 / two mins
gas rate
kw net
kw gross
m3 / two mins
gas rate
kw net
kw gross
m3 / two mins
gas rate
kw net
kw gross
0.001
0.031
0.061
0.092
0.152
0.002
0.032
0.062
0.094
0.154
0.003
0.033
0.063
0.096
0.156
0.004
0.034
0.064
0.098
0.158
0.005
0.035
0.065
0.1
0.16
0.006
0.036
0.066
0.102
0.162
0.007
0.037
0.067
0.104
0.164
0.008
0.038
0.068
0.106
0.166
0.009
0.039
0.069
0.108
0.168
0.01
0.04
0.07
0.11
0.17
0.011
0.041
0.071
0.112
0.172
0.012
0.042
0.072
0.114
0.174
0.013
0.043
0.073
0.116
0.176
0.014
0.044
0.074
0.118
0.178
0.015
0.045
0.075
0.12
0.18
0.016
0.046
0.076
0.122
0.182
0.017
0.047
0.077
0.124
0.184
0.018
0.048
0.078
0.126
0.186
0.019
0.049
0.079
0.128
0.188
0.02
0.05
0.08
0.13
0.19
0.021
0.051
0.081
0.132
0.192
0.022
0.052
0.082
0.134
0.194
0.023
0.053
0.083
0.136
0.196
0.024
0.054
0.084
0.138
0.198
0.025
0.055
0.085
0.14
0.2
0.026
0.056
0.086
0.142
0.202
0.027
0.057
0.087
0.144
0.204
0.028
0.058
0.088
0.146
0.206
0.029
0.059
0.089
0.148
0.208
0.03
0.06
0.09
0.15
0.21
IMPERIAL METER GAS RATES
12
>
41
>
>
>
>
secs / 1ft3
gas rate
kw net
kw gross
secs / 1ft3
gas rate
kw net
kw gross
secs / 1ft3
gas rate
kw net
kw gross
secs / 1ft3
gas rate
kw net
kw gross
secs / 1ft3
gas rate
kw net
kw gross
12
42
72
102
162
13
43
73
104
166
14
44
74
106
170
15
45
75
108
174
16
46
76
110
178
17
47
77
112
182
18
48
78
114
186
19
49
79
116
190
20
50
80
118
194
21
51
81
120
198
22
52
82
122
202
23
53
83
124
206
24
54
84
126
210
25
55
85
128
214
26
56
86
130
218
27
57
87
132
222
28
58
88
134
226
29
59
89
136
230
30
60
90
138
234
31
61
91
140
238
32
62
92
142
242
33
63
93
144
246
34
64
94
146
250
35
65
95
148
254
36
66
96
150
258
37
67
97
152
262
38
68
98
154
266
39
69
99
156
270
40
70
100
158
274
41
71
101
160
278
FLUED APPLIANCES
VENTS WITH RECTANGULAR HOLES
HEAT INPUT
IF MORE THAN ONE APPLIANCE IS FITTED ,INSERT THE TOTAL HEAT INPUT
HOLE SIZE 1
LENGTH (MM)
WIDTH (MM)
NO# OF HOLES
NET
or
GROSS
TO OUTSIDE
TOP VENT
BOTTOM VENT
HOLE SIZE 2
LENGTH (MM)
WIDTH (MM)
NO# OF HOLES
OPEN FLUED IN A ROOM
CM2
OPEN FLUED COMPARTMENT TO OUTSIDE
CM2
HOLE SIZE 3
LENGTH (MM)
WIDTH (MM)
NO# OF HOLES
OPEN FLUED COMPARTMENT VIA ROOM
CM2
TOP VENT
BOTTOM VENT
ROOM SEALED COMPARTMENT TO OUTSIDE
CM2
VENT SIZE
cm2
ROOM SEALED COMPARTMENT VIA ROOM
CM2
DFE FIRES IN ON ROOM
ENTER HOW MANY FIRES ARE FITTED IN THE SAME ROOM
CONSULT MANUFACTURERS INSTRUCTIONS **
CM2
LENGTH
WIDTH
FLUELESS APPLIANCES
OPENABLE WINDOW OR SIMILAR REQUIRED
COOKER ROOM VOLUME
m3
LENGTH
IS A DOOR TO OUTSIDE FITTED X FOR YES
CM2
WIDTH
FLUELESS WATER HEATER ROOM VOLUME
m3
CM2
FLUELESS SPACE HEATERS
CONSULT MANU
FACTURERS INSTRUCTIONS **
VENTS WITH CIRCULAR HOLES
INSERT Kw OF THE APPLIANCE
HOLE SIZE 1
DIAMETER (MM)
NO# OF HOLES
IN A ROOM
MAX 45 W/m3
MAX 90 W/m3
DOES IT CONFORM TO BS EN 449
CM2
CM2
X FOR YES
VENT SIZE
cm2
MULTIPLE APPLIANCES
Flueless space heating**
open flued space heating**
any other appliances
CM2
CM2
CM2
VENT TO OUTSIDE SIZE REQUIRED
CM2
space heating is
CH BOILER, WARM AIR HEATER, FIRE OR SPACE HEATER **
PURGING
INSERT PIPE LENGTHS AND METER TYPE
Piurge calculation only required if a length is inserted in one of the orange boxes 35mm copper, 32mm steel, 32mm MDPE or a U16 meter is used.
Meter type
G4 / U6
x
0.008
0.01
PUT AN X IN THE BOX BESIDE THE METER TYPE
U16
0.025
0.03
E6
0.0024
0.0036
COPPER PIPE
LENGTH IN M
STEEL PIPE
LENGTH IN M
MDPE PIPE
LENGTH IN M
15mm
0.00014
"0"
15mm
½
0.00024
20mm
0.00019
22mm
0.00032
"0"
20mm
¾
0.00046
25mm
0.00033
28mm
0.00054
"0"
25mm
1
0.00064
32mm
0.00053
35mm
0.00084
"0"
32mm
1¼
0.0011
`
"0"
"0"
"0"
Total installation volume M3
"0"
Total purge volume M3
""
Data
""
or imperial
ft3
""
""
""
""
""
COMBUSTION PERFORMANCE ANALYSIS
Co2 %
Co PPM
o2 %
AUTO co/co2 ratio
OR
INSERT CO/CO2 RATIO
BS 7967-3
APPLIANCE TYPE
CO/CO2
RATIO
Back boiler unit
Boiler
0.008
In combination with fire
0.02
Central heating boiler
0.008
Hot water circulator
0.01
Flued space heater
(check man instructions)
0.02
Flueless space heater
0.001
Water heater flued and Flueless
0.02
Warm air heater
0.008
Flueless cooker
Oven
0.008
Hob
Visual inspection of flames
Grill (CE marked)
0.01
Grill (No CE mark)
0.02
Range oven flued
0.02
Refrigerator (LPG)
0.007
Tumble drier
Flued
0.01
flueless
0.001
Gas lights (LPG)
0.02
Update
Reset
Print This